计算溶液所需的质量、体积或浓度。
多重微球活化试剂盒
库存信息
| 货号 (SKU) | 包装规格 | 是否现货 | 价格 | 数量 |
|---|---|---|---|---|
| A487967-10Sets |
10套 |
期货 ![]() |
|
| 货号 (SKU) | 包装规格 | 是否现货 | 价格 | 数量 |
|---|---|---|---|---|
| A487967-10Sets |
10套 |
期货 ![]() |
|
| 英文名称 | Activation Kit For Multiplex Microspheres |
|---|---|
| 储存温度 | 2-8°C储存 |
| 运输条件 | 冰袋运输 |
| 产品介绍 |
Description AnteoTech identified the following problems that researchers are having with their multiplex assays:Binding difficult antibodies and antigens to microspheresComplex protocols for inexperienced usersLengthy microsphere and protein preparation times prior to protein couplingReproducibility between batches of protein coupled microspheresLimited storage of ready-to-couple microspheresFrom these findings, they developed the AnteoBind™Activation Kit For Multiplex Microspheres that is for use with the Luminex xMAP®system and contains the patented AnteoBind Activation Reagent.With this Activation Kit, you can couple multiple antibodies without extra optimization for each, saving assay development time and reducing the barriers of assay transfer between diverse platforms.AnteoBind is water based and replaces the dry chemicals you would use with the EDC method. Using AnteoBind instead of NHS/EDC chemistry can save up to 3-4 hours of lab time. Experiments have shown increased stability and functionality for antibodies and a decreased background. AnteoBind improves reproducibility between experiments by providing uniformity between surfaces. You can store your AnteoBind activated microspheres for up to 1 year.POSTER: A Novel User Friendly Chemistry to Couple Antibodies and Challenging Proteins to Luminex MagPlex MicrospheresActivation and coupling of Luminex Microspheres for Multiplex Immunoassays Description AnteoTech identified the following problems that researchers are having with their multiplex assays:Binding difficult antibodies and antigens to microspheresComplex protocols for inexperienced usersLengthy microsphere and protein preparation times prior to protein couplingReproducibility between batches of protein coupled microspheresLimited storage of ready-to-couple microspheresFrom these findings, they developed the AnteoBind™Activation Kit For Multiplex Microspheres that is for use with the Luminex xMAP®system and contains the patented AnteoBind Activation Reagent.With this Activation Kit, you can couple multiple antibodies without extra optimization for each, saving assay development time and reducing the barriers of assay transfer between diverse platforms.AnteoBind is water based and replaces the dry chemicals you would use with the EDC method. Using AnteoBind instead of NHS/EDC chemistry can save up to 3-4 hours of lab time. Experiments have shown increased stability and functionality for antibodies and a decreased background. AnteoBind improves reproducibility between experiments by providing uniformity between surfaces. You can store your AnteoBind activated microspheres for up to 1 year.POSTER: A Novel User Friendly Chemistry to Couple Antibodies and Challenging Proteins to Luminex MagPlex MicrospheresActivation and coupling of Luminex Microspheres for Multiplex Immunoassays |
| 1. Katrin Bohm, Angela Filomena, Nicole Schneiderhan-Marra, Gérard Krause, Claudia Sievers,. (2017-09-19) Validation of HAV biomarker 2A for differential diagnostic of hepatitis A infected and vaccinated individuals using multiplex serology.. Vaccine, 35 ((43)): ( 5883-5889 ). [PMID:28919226] |